6.3

EDIT mode

The following settings can be undertaken in the EDIT mode:

Ĉ the switching function (threshold value or window comparator)

Ĉ the switching points [SP], switching point [SP] with LS−active or [SP] [min] and [SP] [max]

Ĉ the hysteresis [HY], hysteresis [HY] with LS−active

Ĉ the switching characteristic [NO/NC] (normally−open/normally−closed)

Ĉ the air−save function [OPTION] ON/OFF

Ĉ the security code (Lock)

Ĉ the duration of the reject pulse

Ĉ the permitted pressurization time

Ĉ the permitted evacuation time

Ĉ activating the diagnostic output

Ĉ electric manual override.

Note

If the air−save function (−CE, −OE) is active, their settings will be undertaken in the menu

of Out A. If the air−save function is deactivated, Out A is a normal switch output.

6.3.1

Start the EDIT mode

Warning

Depending on the functions of the machine/system, the manipulation of signal states

can cause serious injury to human beings and damage to property.

· Note that if the switching reaction of the switching outputs is modified in the

EDIT mode, the new status will be effective immediately.

Various settings can be selected with the operating buttons (è Fig. 13: )

Ĉ Output (Out A, Out B), the reaction of which is to be set.

Ĉ The duration of the reject pulse.

Ĉ Special menu (SPEC) for setting the air−save function option (LS option), the maximum evacuation

and pressurization times and the security code (Lock).

Note

If the air−save function is active (factory setting only −CE, −OE), the function window

comparator for Out A cannot be set. The air−save function must be deactivated via the

special menu (SPEC).