Fitting

The valve terminal can be fitted in any position. Mount and connect the tubing of the vacuum generator

so that no condensation from the compressed air lines can gather in the device.

4.1

Mechanical installation

4.1.1

Direct fastening

Fig. 7: Direct fastening

· Mount the vacuum generator with two screws at the intended location (size of the mounting screws

è

Tab. 5: ), tightening torque max. 2.5 Nm.

We recommend that suitable washers be used.

or

· Fasten the vacuum generator at the bottom with four M5 screws, tightening torque max. 0.8 Nm.

OVEM

Size of mounting screws

05/07/10

M5

14

M4

Tab. 5: Size of mounting screws