OVEM

70

Festo ć OVEM ć 1004b English

2.7

Measured variables

Vacuum

Measurement is made continuously between the vacuum connection and the filter

(measured signal In A1).

Minimum/maximum value

The minimum and maximum measured pressure values (vacuum) are saved in the vacuum generator.

The values will be lost if the supply voltage for the vacuum generator is switched off.

Cycle

A cycle lasts from the beginning of the evacuation through the rejection up till the beginning of the next

evacuation (è Fig. 6: ).

In

Out A

3

4

1

2

2

5

Suction

1

Cycle

2

Evacuation time t

evac

3

Pressurization time t

bel

4

Switch−on point Out A

5

Switch−off point Out A

Fig. 6: Definition cycle, example for Out A

Pressurization and evacuation times

The minimum and maximum pressurization and evacuation times are measured in the vacuum

generator. The values will be lost if the vacuum generator is switched off.