Method of operation of the air−save function (ls) – Festo Генератор вакуума OVEM, дюймовый Benutzerhandbuch

Seite 67

Advertising
background image

OVEM

Festo ć OVEM ć 1004b English

67

Variant

Switch input

Switch output B

Switch output A

Diagnosis

−2N

Message

finished

Switch output

negative−switching

Pressure sensor

outputĂA

Switch output

negative−switching

Pressure sensor

outputĂB

Switch input

negative−switching

Message

on

p

Switch output

negative−switching

Diagnostic message

−NI

ć

Analogue output

4

Ū 20 mA

Vacuum

−NU

ć

Analogue output

0

Ū 10 V

Vacuum

Tab. 3: Variants of switch outputs

2.4

Method of operation of the air−save function (LS)

· Check whether the air−save function can be used (saving energy).

This function is only possible with units −CE and −OE. The air−save function is activated at the factory.

The air−save function can be switched off (è chapter 6.3.4).

If the desired threshold value

1 for the vacuum is reached, the vacuum generation will be switched off

automatically. A non−return valve prevents reduction of the vacuum. As a result of leakage (e.g. due to

rough work item surfaces), the vacuum will be reduced slowly. If the set threshold value

3 is not

reached, vacuum generation will be switched on automatically. Vacuum will be generated until the set

threshold value

1 is reached again.

Fig. 5: clarifies the method of operation of the air−save function. The pressure curve with the threshold

values and limits is represented in the upper part of the graph. The relevant signals In (control input

signal) and Out A (message signal outwards) are shown in the lower part of the graph.