2 diagnosis, Diagnosis – Festo Генератор вакуума OVEM, дюймовый Benutzerhandbuch

Seite 97

Advertising
background image

OVEM

Festo ć OVEM ć 1004b English

97

Cleaning the air filter

1

2

Fig. 21: Fitting/removing the filter

1. Exhaust the vacuum generator.

2. Pull the slide

1 of the filter 2 out carefully to the first grid mark. The slide 1 must remain in this

position on the filter.

3. Pull the filter out. (If necessary assist removal of the filter with a screwdriver.)

4. Clean the filter

2 with petroleum ether.

5. Push the filter

2 with slide 1 into the housing.

6. Press in the slide

1.

è

The filter is pulled in through the slide

1.

8.2

Diagnosis

There are four different diagnostic stages. There are two possibilities of displaying the relevant

diagnostic messages:

· via the logical diagnosis channels di 1 and di 2 of the output Out B (only with −2P and −2N);

· via the LCD display of the vacuum generator.

If the diagnostic message at output Out B is desired, the diagnostic channel di 1 or di 2 must be set

(configuration of output Out B è chapter 6.3.2).

Advertising