Sonderfunktionen, Special functions – Grundig GV 460 VPT / NIC Benutzerhandbuch

Seite 68

Advertising
background image

Servicetestprogramm und Sonderfunktionen / Service Test Programme and Special Functions

GV44…, GV45…, GV46…

1 - 68

GRUNDIG Service-Technik

Code

Function

Number

8501

Continuous soak test "Playback" up to the

tape counter reading when the soak test was

started (Start the test with button

J

)

8501

Continuous soak test (select a programme

position and press button

M

I

;

)

8510

V-pulse insertion "OFF"

8511

V-pulse insertion "ON"

8516

Remote control address "VIDEO 1"

(refer to the Operating Book)

8517

Remote control address "VIDEO 2"

(refer to the Operating Book)

8518

Modulator "OFF"

8519

Modulator "ON"

8526

10 and 16 bit transmitter commands are

accepted

8527

16 bit transmitter commands are accepted

8528

Adjustment of the V-pulse insertion

(refer to the Operating Book)

8532

16:9 Automatic "OFF" (for recorders without DOS)

8533

16:9 Automatic "ON" (for recorders without DOS)

8546

No line interlacing (312 / 312) – eg. for CTV

models with 50Hz frame frequency

8547

With line interlacing (312 / 313) – eg. for

CTV models with 100Hz frame frequency

8560

NICAM Test sound "OFF"

(only for recorders with NICAM Decoder)

8561

NICAM Test sound "ON"

(only for recorders with NICAM Decoder)

8562

Piezo Sound "OFF" (city line)

8563

Piezo Sound "ON" (city line)

8570

Manual tuning

(refer to the Operating Book)

8571

Station search (refer to the Operating Book)

8587

Remote control of “Shuttle” functions is

possible with the Shuttle ring or with the

buttons

F

G

8588

Remote control of the "Picture Search"

function is possible with the Shuttle ring or

with the buttons

F

G

8528

>

Data Programmer (new)

2. Sonderfunktionen

Aufrufen der Sonderfunktionen
– Auf dem Fernbediengeber die Taste

Z

drücken

– Codenummer eingeben
– Taste

O

bzw.

>

(für Data-Programmer) drücken.

Löschen der Dauerlauffunktionen
– Taste

b

drücken, Sonderfunktion wird abgebrochen.

Aktivieren des Zahlenschlosses
– Auf dem Fernbediengeber Taste

D

drücken

– "4-stellige Geheimzahl" eingeben und Taste

O

drücken (im Dis-

play erscheint "

LOCKED

").

Zahlenschloß entriegeln
– Auf dem Fernbediengeber Taste

D

drücken

– "4-stellige-Geheimzahl" eingeben und Taste

O

drücken.

Entriegeln bei unbekanntem Zahlencode
– Auf dem Fernbediengeber Taste

Z

drücken

– Zahlenfolge

4

9

3

4

eingeben

– Taste

O

drücken.

2. Special Functions

Calling up the Special Functions
– Press the

Z

button on the remote control

– Feed in the Code number
– Depress the

O

or

>

(for Data Programmer) button.

Erasing the Continuous Soak Test Functions
– Press the button

b

, "Special Function" is terminated.

Activating the Security Code
– Press the

D

button on the remote control

– Feed in the "4-position Security Code" and depress the

O

button

("

LOCKED

" is indicated in the display).

Cancelling the Security Code
– Press the

D

button on the remote control

– Feed in the "4-position Security Code" and depress the

O

button.

Cancelling an Unknown Number Code
– Press the

Z

button on the remote control

– Enter the numbers

4

9

3

4

sequentially

– Depress the

O

button.

Code-

Funktion

Nummer

8501

Dauerlauffunktion "Wiedergabe" bis zum

Bandzählerstand bei Dauerlaufbeginn

(Dauerlauf starten mit der Taste

J

)

8501

Dauerlauf "Aufnahme" (Programmplatz

wählen und die Tasten

M

I

;

drücken)

8510

V-Impuls-Eintastung "AUS"

8511

V-Impuls-Eintastung "EIN"

8516

Bedienebene "VIDEO 1"

(siehe Bedienungsanleitung)

8517

Bedienebene "VIDEO 2"

(siehe Bedienungsanleitung)

8518

Modulator "AUS"

8519

Modulator "EIN"

8526

10- und 16-Bit-Geberbefehle werden

angenommen

8527

16-Bit-Geberbefehle werden angenommen

8528

Abgleich der V-Impuls-Eintastung

(siehe Bedienungsanleitung)

8532

16:9 Automatik "AUS" (bei Geräten ohne DOS)

8533

16:9 Automatik "EIN" (bei Geräten ohne DOS)

8546

Ohne Zeilensprung (312 / 312) – z. B. für

Geräte mit 50Hz Bildwechselfrequenz

8547

Mit Zeilensprung (312 / 313) – z. B. für

Geräte mit 100Hz Bildwechselfrequenz

8560

NICAM-Testton "AUS"

(nur bei Geräten mit NICAM-Decoder)

8561

NICAM-Testton "EIN"

(nur bei Geräten mit NICAM-Decoder)

8562

Piezo-Ton "AUS" (city line)

8563

Piezo-Ton "EIN" (city line)

8570

Manuelle Senderabstimmung

(siehe Bedienungsanleitung)

8571

Sendersuchlauf (siehe Bedienungsanleitung)

8587

Fernbedienung der "Shuttle"-Funktionen ist

möglich über das Shuttle-Rad bzw. über die

Tasten

F

G

8588

Fernbedienung des "Bildsuchlaufes" ist

möglich über das Shuttle-Rad bzw. über die

Tasten

F

G

8528

>

Data-Programmer (neu)

Display

zeigt

CONT

CONT

OFF

ON

VIDEO1

VIDEO2

OFF

ON

VIDEO

VIDEO

JITTER

4X3

16X9

OFF

ON

OFF

ON

OFF

ON

TUNING

SEARCH

OFF

ON

IRDATA

Display

shows

CONT

CONT

OFF

ON

VIDEO1

VIDEO2

OFF

ON

VIDEO

VIDEO

JITTER

4X3

16X9

OFF

ON

OFF

ON

OFF

ON

TUNING

SEARCH

OFF

ON

IRDATA

Advertising
Dieses Handbuch ist für die folgenden Produkte bezogen werden: