Abgleichvorschriften / Adjustment Procedures

GV44…, GV45…, GV46…

3 - 6

GRUNDIG Service-Technik

2.2 Family Board – DOS (OS)

Test Equipment: Two-channel Oscilloscope, 1:1 Test Probe (TK).

Service work after replacing the Family Board:

Adjustment

Preparation

Adjustment Procedure

1. H/2 Sync

Adjustment, F1040
(necessary after
replacing F1040 or
C2167)

Set the time interval with F1040 between the middle of the
H/2-SYNC (IC7190-(7)) pulse and the negative going edge
of the SYNC (IC7190-(10)) to

t = 32

µ

s

±

10

µ

s.

64

µ

s

t

IC7190-(7)

IC7190-(10)

Oscilloscope:
Channel 1: .................................................... IC7190-(10)
Channel 2: ...................................................... IC7190-(7)
Trigger: ....................... Channel 2, negative going edge.
Feed in a HF signal (PAL) / Record or EE mode without
Texttable.

2.3 Family Board – Frontend (FE)

Test Equipment: Oscilloscope (>50MHz), 10:1 Test Probe, Voltmeter, Colour Generator with Stereo Coder, Distortion Factor Meter, Stabilized Power
Supply.

Service work after replacing the Tuner: Adjustment no. 2

Adjustment

Preparation

Adjustment Procedure

1. Vision Demodula-

tor Circuit, F1175
(AFC-ADJ)

2. Delayed AGC

Voltage, R4140
(AGC-ADJ)

3. Quasi-Split-Sound

(QSS), F1145
(REF-ADJ)

4. FM-Demodulator

(FM-Sound 1),
F1155 (FM1-ADJ)

5. FM-Demodulator

(FM-Sound 2),
F1180 (FM2-ADJ)

6. Cross Talk

7. ATS-Adjustment

Set the voltage with F1175 (AFC-ADJ) to 2.5V

±

0.1V.

Set the amplitude with R4140 (AGC-ADJ) to 40mV

PP

.

Unsolder the 4.7pF capacitor.

Set the distortion with F1145 (REF-ADJ) to Minimum
(or adjust for best sine wave possible on the oscilloscope).

Set the distortion with F1155 (FM1-ADJ) to Minimum
(or adjust for best sine wave possible on the oscilloscope).

Set the distortion with F1180 (FM2-ADJ) to Minimum
(or adjust for best sine wave possible).

Set the cross talk to Minimum:
Coarse: with remote control button

1

= "

L †

",

2

= "

L --

"

Fine: with remote control button

3

= "

S †

",

4

= "

S --

"

To cancel the service function: Press the "Standby" button
or disconnect the recorder from the mains.

Press the button

7

. The display shows "

ATS† 00 00 A7

".

To cancel the service function: Press the "Standby" button
or disconnect the recorder from the mains.

Initializing the RAM and EEPROM (2.1 Sequence Control
/Deck Electronic – Adjustment no. 1)
Power Supply, 2.3V (AFC disabled): ........... IC7050-(24)
Feed in a TV standard test pattern (Ch12, Ch21, Ch68, Ch8
or Ch60; see "Initializing the RAM and EEPROM").
Voltmeter: ........................................................... MP

86

EE mode.

Solder a 4.7pF capacitor to MP

87

. Connect the oscilloscope

with 10:1 test probe to the free connection of the capacitor.
Feed in a standard test pattern without audio modulation (UHF-
range, Ch26, 67dB

µ

V aerial signal) into a warmed-up set.

EE mode

Feed in a standard test pattern (UHF-range, Ch26, aerial
signal >60dB

µ

V ) into a warmed-up set.

Distortion factor meter (or oscilloscope)
with 10:1 test probe: ........................................... MP

82

EE mode

Feed in a 2-channel sound standard test pattern with the
colour generator, 1kHz sine,

±

27kHz deviation.

Distortion factor meter (or oscilloscope): ........... MP

82

EE mode.

Feed in a 2-channel sound standard test pattern with the
colour generator, 1kHz sine,

±

27kHz deviation.

Distortion factor meter (or oscilloscope): ........... MP

83

EE mode.

Feed in a standard test pattern with sound modulation
"stereo".
Oscilloscope: ...................................................... MP

82

RF recording.
Call up the service function:
– Press the

Z

button on the remote control handset

("

CODE – – – –

" is indicated in the display).

– Enter the code number

4

9

3

4

and press the

O

button ("

SERV

" is indicated in the display).

Feed in a standard test pattern (UHF-range, Ch26, 50dB

µ

V

aerial signal).
RF recording.
Call up the service function:
– Press the

Z

button on the remote control handset

("

CODE – – – –

" is indicated in the display).

– Enter the code number

4

9

3

4

and press the

O

button ("

SERV

" is indicated in the display).

Advertising