Adjustment procedures, Power supply (ps), Family board – Grundig GV 460 VPT / NIC Benutzerhandbuch

Seite 89

Advertising
background image

GV44…, GV45…, GV46…

Abgleichvorschriften / Adjustment Procedures

GRUNDIG Service-Technik

3 - 5

GB

Adjustment Procedures

1. Power Supply (PS)

Test Equipment: Digital Voltmeter.

Service work after replacing the Power Supply:

Adjustment

Preparation

Adjustment Procedure

+12V

D

Adjust voltage to 12V

±

0.1V with R3090.

Digital voltmeter: .................................................. MP

1

Playback.

2. Family Board

Service work after replacing the Family Board:
– 2.1 Sequence Control ..................................... Adjustment no. 1, 2
– 2.4 Video ........................................................ Adjustment no. 3, 5
– 2.6 FM Sound ................................................. Adjustment no. 2, 3
– 2.7 Standard Sound ....................................... Adjustment no. 1…4

2.1 Family Board – Sequence Control /Deck Electronic (DE)

Test Equipment: Oscilloscope, 10:1 Test Probe, Frequency Counter.

Service work after changing:

– Family Board: Adjustment no. 1, 2

– the IC7058: Adjustment no. 1

2.3 Frontend – Adjustment no. 6, 7

– the IC7060: Adjustment no. 1…3

2.4 Video – Adjustment no. 5

Adjustment

Preparation

Adjustment Procedure

Press the buttons

>

and

V

simultaneously on the recorder and connect the mains plug.

In doing so, the following channels are set on the first 5 programme positions for frontend adjustment (vision
demodulator circuit):
Programme 1 – channel 12; programme 2 – channel 21; programme 3 – channel 68
programme 4 – channel 8; programme 5 – channel 60

Warning: This function erases all data entered by the customer (stations selected, …)!

– Load a test cassette. The video recorder then switches automatically to play mode.
– Call up the service function:

– Press the

Z

button on the remote control handset ("

CODE – – – –

" is indicated in the display).

– Enter the code number

4

9

3

4

and press the

O

button ("

SERV

" is indicated in the display).

– Press the

3

button.

During the automatic adjustment of the headwheel position indicator the display shows "

DRUM 00

00

A3

".

On successful adjustment the video recorder ejects the test cassette.

– To cancel the service function: Mains reset or press the "Standby" button.

Connect IC7060-(7) to +5V

D

via a 10k

resistor.

Frequency counter to IC7060-(7).
Standby.

1. Initializing the

RAM (IC7060) and
EEPROM (IC7058)

2. Headwheel

Position Indicator

3. Clock, C2060

Set clock period to 1s

±

4

µ

s via C2060. Remove the 10k

resistor.

Advertising