4 family board – video (vs), 5 family board – chroma (vs) – Grundig GV 460 VPT / NIC Benutzerhandbuch

Seite 91

Advertising
background image

GV44…, GV45…, GV46…

Abgleichvorschriften / Adjustment Procedures

GRUNDIG Service-Technik

3 - 7

2.4 Family Board – Video (VS)

Test Equipment: Oscilloscope, 10:1 Test Probe, Frequency Counter, Stabilized Power Supply, Colour Generator, Test Cassette.

Service work after replacing the Family Board: Adjustment no. 3, 5

Adjustment

Preparation

Adjustment Procedure

1. EE-Level / Sync-

Level Control,
R3635 (EE)

2.1 Frequency

Deviation Sync
Value, R3752
(SV)

2.2 White Value,

R3755 (WV)

3. Video Record

Voltage, R3707
(YWV)

4. Playback Amplitu-

de, R3768 (PBA)

5. FM-Reference

Level Adjustment
for Automatic
Contour Control

Set amplitude with R3635 (EE) to 0.5V

PP

.

Set frequency counter with R3752 (SV) to 3.8MHz.
Solder in C2605.

Increase the voltage of the power supply slowly, till both
beams coincide.
Set frequency counter to 4.85MHz with R3755 (WV).
Solder in C2605.

Set FM signal with R3707 (YWV) to 0.22V

PP

.

Set amplitude with R3768 (PBA) to 2V

PP

.

Press the button

1

. The display shows on the left "

PICT

"

and on the right "

A1

". On successful adjustment the video

recorder switches to Pause
To cancel the service function: Press the "Standby" button
or disconnect the recorder from the mains.

Feed in a white test pattern (100% white, 1V

PP

, 0.3V sync

component, 0.7V CVS component).
Oscilloscope: ...................................................... MP

31

AV recording.

Unsolder C2605.
Frequency counter: ............................................. MP

32

AV recording.

Frequency counter: ............................................. MP

32

Oscilloscope:

Channel A:

IC7510-(42),

Channel B:

Marking beam

Trigger:

IC7510-(33), switch
oscilloscope to DC.

AV recording.
Mark the white value of the CVS signal with the unused
beam B of the oscilloscope.
Unsolder C2605.
Power Supply: Connect positive (0V) to IC7510-(42) via

a diode; cathode of the diode to pin 42.
Connect negative to chassis.

Oscilloscope: ............................. Head Amplifier, MP

1

AV recording.

Oscilloscope: ...................................................... MP

33

Play back a white test pattern (self-made recording).

Playback
Call up the service function:
– Press the

Z

button on the remote control handset

("

CODE – – – –

" is indicated in the display).

– Enter the code number

4

9

3

4

and press the

O

button ("

SERV

" is indicated in the display).

2.5 Family Board – Chroma (VS)

Test Equipment: Oscilloscope with 10:1 Test Probe.

Service work after replacing the Family Board:

Adjustment

Preparation

Adjustment Procedure

1. Chroma Record

Voltage, R3693
(CWV)

2. 627kHz Comb

Filter, R3918 (CF)

Set amplitude with R3693 (CWV) to 55mV

PP

.

Remove the short circuit.

With R3918 (CF) set the signal as shown in the oscillo–
grams below.

Incorrect

CORRECT

Incorrect

200

µ

s/cm

Short-circuit C2552.
Feed in a colour bar test pattern.
Oscilloscope: ............................. Head Amplifier, MP

1

Record.

Oscilloscope: ...................................................... MP

41

Trigger: ................................................. HI pulse 1506-3.
Play back a self-made recording (red test signal).