Specifications – WIKA TR10-C Benutzerhandbuch

Seite 11

Advertising
background image

WIKA operating instructions resistance thermometers and thermocouples, Ex n

14106886.01 06/2014 GB/D

11

GB

Moreover, this standard specifies the basic values in °C steps in tabular form.

Class

Temperature range

Tolerance value in °C

Wire-wound (W)

Thin-film (F)

B

-196 … +600 °C

-50 … +500 °C

±(0.30 + 0.0050 | t |)

1)

A

-100 … +450 °C

-30 … +300 °C

±(0.15 + 0.0020 | t |)

1)

AA

-50 … +250 °C

0 … 150 °C

±(0.10 + 0.0017 | t |)

1)

1) | t | is the value of the temperature in °C without consideration of the sign.

Bold: Standard version

For further technical information, see WIKA data sheet and Technical information IN 00.17

“Usage limitations and accuracies of platinum resistance thermometers per EN 60751: 2008”.

3.2 Thermocouples
3.2.1 Sensor type

Type

Recommended max. operating temperature

K

1,200 °C

J

800 °C

E

800 °C

T

400 °C

N

1,200 °C

S

1,600 °C

R

1,600 °C

B

1,700 °C

Tolerance values of the thermocouples per IEC 60584-2 / ASTM E230

(Reference temperature 0 °C)

Type Thermo-

couple

Tolerance value Class

Temp. range

Tolerance value

K

N

NiCr-NiAl

(NiCr-Ni)

NiCrSi-NiSi

IEC 60584 part 2

1

-40 ... +1,000 °C ±1.5 °C or 0.0040 | t |

1) 2)

2

-40 ... +1,200 °C ±2.5 °C or 0.0075 | t |

ASTM E230

Special

0 ... +1,260 °C ±1.1 °C or ±0.4 %

Standard 0 ... +1,260 °C ±2.2 °C or ±0.75 %

J

Fe-CuNi

IEC 60584 part 2

1

-40 ... +750 °C ±1.5 °C or 0.0040 | t |

2

-40 ... +750 °C ±2.5 °C or 0.0075 | t |

ASTM E230

Special

0 ... +760 °C ±1.1 °C or ±0.4 %

Standard 0 ... +760 °C ±2.2 °C or ±0.75 %

E

NiCr-CuNi

IEC 60584 part 2

1

-40 ... +800 °C ±1.5 °C or 0.0040 | t |

2

-40 ... +900 °C ±2.5 °C or 0.0075 | t |

ASTM E230

Special

0 ... +870 °C ±1.0 °C or ±0.4 %

Standard 0 ... +870 °C ±1.7 °C or ±0.5 %