Sicherheit, Tr10-a-andz, Tc10-a-andz – WIKA TR10-C Benutzerhandbuch
Seite 35: Tr10-b-anhz, Tc10-b-anhz, 2 typenschilder für thermoelemente, Typenschild für messeinsatz tc10-a, Zusätzliche angaben für ex-geräte

TR10-B-ANHZ
1 x Pt100 / A / 3 (W)
-100 ... +450 °C
EN 60751
Made in Germany
1105WAU0
T32.1S.0NI 4 ... 20 mA
-50 ... +250 °C
WARNING: DO NOT OPEN WHILE ENERGIZED!
2014
II 3G Ex nA IIC T1...T6 Gc X
T6/T5/T4-T1: -20 °C < Ta < +55/+70/+80 °C
II 3D Ex tc IIIC T440°C...T80°C Dc X
2014 11012345
TR10-A-ANDZ
EN 60751
1 x Pt100 / A / 4
-50 ... +250 °C
D = 6 mm
525 mm
(W)
II 3G Ex nA IIC T1 ... T6 Gc X
2014 11012345
TC10-A-ANDZ
EN 60584-1
1 x Type K / 1 / .
0 ... 1260 °C
D = 6 mm
525 mm
II 3G Ex nA IIC T1 ... T6 Gc X
2014
TC10-B-ANHZ
1 x Type K / 1 / .
0 ... 1260 °C
EN 60584-1
Made in Germany
1105WAU0
T32.1S.0NI 4 ... 20 mA
0 ... 500 °C
2014
T80/95/130-440°C: -20 °C < Ta < +55/+70/+80 °C
TR10-B-ANHZ
1 x Pt100 / A / 3 (W)
-100 ... +450 °C
EN 60751
Made in Germany
1105WAU0
T32.1S.0NI 4 ... 20 mA
-50 ... +250 °C
WARNING: DO NOT OPEN WHILE ENERGIZED!
2014
II 3G Ex nA IIC T1...T6 Gc X
T6/T5/T4-T1: -20 °C < Ta < +55/+70/+80 °C
II 3D Ex tc IIIC T440°C...T80°C Dc X
2014 11012345
TR10-A-ANDZ
EN 60751
1 x Pt100 / A / 4
-50 ... +250 °C
D = 6 mm
525 mm
(W)
II 3G Ex nA IIC T1 ... T6 Gc X
2014 11012345
TC10-A-ANDZ
EN 60584-1
1 x Type K / 1 / .
0 ... 1260 °C
D = 6 mm
525 mm
II 3G Ex nA IIC T1 ... T6 Gc X
2014
TC10-B-ANHZ
1 x Type K / 1 / .
0 ... 1260 °C
EN 60584-1
Made in Germany
1105WAU0
T32.1S.0NI 4 ... 20 mA
0 ... 500 °C
2014
T80/95/130-440°C: -20 °C < Ta < +55/+70/+80 °C
TR10-B-ANHZ
1 x Pt100 / A / 3 (W)
-100 ... +450 °C
EN 60751
Made in Germany
1105WAU0
T32.1S.0NI 4 ... 20 mA
-50 ... +250 °C
WARNING: DO NOT OPEN WHILE ENERGIZED!
2014
II 3G Ex nA IIC T1...T6 Gc X
T6/T5/T4-T1: -20 °C < Ta < +55/+70/+80 °C
II 3D Ex tc IIIC T440°C...T80°C Dc X
2014 11012345
TR10-A-ANDZ
EN 60751
1 x Pt100 / A / 4
-50 ... +250 °C
D = 6 mm
525 mm
(W)
II 3G Ex nA IIC T1 ... T6 Gc X
2014 11012345
TC10-A-ANDZ
EN 60584-1
1 x Type K / 1 / .
0 ... 1260 °C
D = 6 mm
525 mm
II 3G Ex nA IIC T1 ... T6 Gc X
2014
TC10-B-ANHZ
1 x Type K / 1 / .
0 ... 1260 °C
EN 60584-1
Made in Germany
1105WAU0
T32.1S.0NI 4 ... 20 mA
0 ... 500 °C
2014
T80/95/130-440°C: -20 °C < Ta < +55/+70/+80 °C
WIKA Betriebsanleitung Widerstandsthermometer und Thermoelemente, Ex n
14106886.01 06/2014 GB/D
35
2.5.2 Typenschilder für Thermoelemente
■
Typenschild für Messeinsatz TC10-A
„ungrounded“
isoliert verschweißt
2. Sicherheit
Herstellungsjahr
■
Zusätzliche Angaben für Ex-Geräte
Typ
Sensor
Transmitter-Typ
(nur bei Ausführung mit Transmitter)
Sensor gemäß Norm
Herstellungsjahr
Herstellungsjahr
Typ
Legende:
■
ungrounded
isoliert verschweißt
■
grounded
mit dem Mantel verschweißt (geerdet)
D