minimum maximum

-50 ... -20 -50 ... +250

-40 ... -20 -40 ... +250

0 ... +20 0 ... +250

+10 ... +30 +10 ... +250

+20 ... +50 +20 ... +250

+50 ... +230 +50 ... +250

Measuring range in °C

-50 °C
-40 °C
0 °C
+10 °C
+20 °C
+50 °C

Range of possible upper limits to measuring range in °C

-50 0

+100

+250

Star

t of measuring

range

Diagram for measuring range

With configuration to customer specifications, the measuring range will be shown clearly

on the instrument label. The configuration and the choice of parameters is described in the

menu-driven configuration software. Changes to the configuration must be noted on the

label using a water-resistant felt-tip pen.

Possible combinations of the lower and upper limits of the measuring range

The upper limit of the measuring range is dependent on the respective lower limit of the

measuring range.

For clarity, this dependency has been shown in 50 °C steps in the examples in these

diagrams. The configuration software checks the required measuring range and will only

accept permissible values. Intermediate values are configurable; the smallest increment is

0.1 °C.

7. Configuration of model TR30-W

Please note:

The measuring range of the thermometer is limited by the application range of the

measuring element, not by the adjustable range of the transmitter.

Without neck tube -50 … +150 °C, with neck tube -50 … +250 °C.