10 annex b: register entries of the pcmatic device, 1 introduction to register entries, 2 f-keys – Lenze PCMatic Operating system Windows CE4-2 Benutzerhandbuch
Seite 105

103
10 Annex B: Register entries of the PCMatic device
10.1 Introduction to register entries
The register is not an essential part of the device image, in other words it is possible for user-
specific settings to be saved here and also to be read again following the next system start.
In addition to the manual configuration via the “Config Manager”, there exists a possibility (e.g.
by using the “Script Control”) to automate configuration settings by means of direct entries in the
register.
10.2 F-Keys
The allocation of the F-Keys is expected to be located under the keys
[HKEY_LOCAL_MACHINE\AutomationPanel\HotKeys\Shift F1 ... F4].
For each key, there are the following entries:
Instruction Description
Type
Function
For each key, the functions are given together with the
corresponding Reg. IDs.
Dword
Function Description
Reg.
ID
<none>
No function
0
Start
Program
The program indicated under
“Parameter” will be started.
1
Touch
Keyboard
The screen keyboard is switched to be
visible /invisible.
2
Right
Mouseclick
A click (with the right hand mouse
button) is generated at the current
position of the mouse cursor.
3
Run
APScript
The file given in “Parameter” is executed
as a script file by the “Script Control”.
4
AP
Config
Manager
The Config Manager is started and the
filing card given in “Parameter” is
opened.
5
Parameter
The parameter which matches the corresponding function.
String
e.g.: The function key F3 is allocated to the function “Start Program” and the path for the
command line under Windows CE.
[HKEY_LOCAL_MACHINE\AutomationPanel\HotKeys\Shift F3]
"Function"=dword:1
"Parameter"="\windows\cmd.exe"