NE218

32

www.baumer.com

Change

Start count SC

Press the

key.

The current start count SC is displayed for reading.

The LED „SC“ shines.

Enter start count via

and

keys.

Press the

key.

Totalizer ∑

Press the

key.

The current total is displayed for reading.

The LED „∑“ shines.

If the value 999999 is exceeded, its display will be shown in two

steps. 1st step: Display of the first 6 digits. 2

nd

step: marked by an

“H“, display of 7

th

and 8

th

digit.

Display of each value for approx. 3 seconds.

Reset

Press the

key.

Reset

Time meter

Press the

key.

The operating time is displayed for reading.

The LED „ “ shines.

Press the

key.


Change

Scaling factor SF

The scaling factor allows the display of fractions or multiples of the

counting pulses.

Setting range: 0.0001 to 9999.99. Setting ex factory: 1.0000.
Press the

key.

The current scaling factor „SF“ is displayed for reading.

Enter scaling factor „SF“ via

and

keys.

Press the

key.

Example In the case of a length measurement by means of encoder and

cyclometer, the circumference of the cyclometer measures 200

mm and the encoder supplies 500 pulses per revolution. The mea-

surement is to be displayed in mm. The scaling factor is calculated

as follows:

Scaling factor =

Circumference

=

200

= 0.4000

Pulses

500

Press the

key again, the current count XP is re-displayed.