Programming field 3

Here all machine-related functions and values, as well as the inter-

face parameters are programmed.

The factory setting is marked in each case with a *.

Line 22

Operating modes

0 * Step preset

1 Main presets

2 Parallel comparison

3 P1 Self-adjusting preset

Line 24

Decimal point (for XP, P1, P2, SC,

Σ

)

0 * No decimal point

1 00000.0

2 0000.00

3 000.000

4 00.0000

Line 25

Counting mode

0 * Track A and UP/DOWN signal on track B

1 Differential counting, track A adding, track B subtracting (A-B)

2 Totalizing, tracks A and B adding (A+B)

3 Track A 90° track B single evaluation

4 Track A 90° track B twofold evaluation

5 Track A 90° track B fourfold evaluation

To set track A at 90° to track B, the input frequencies for both tracks

must be adjusted to 10 kHz (lines 26 and 27).

Line 26

Frequency main counter track A

0 * 10 kHz

1 25 Hz

2 3 Hz

Line 27

Frequency main counter track B

0 * 10 kHz

1 25 Hz

2 3 Hz

Line 28

Input logic and operating threshold of signal inputs

0 * PNP Switching threshold 10 V

1 NPN Switching threshold 10 V

2 PNP Switching threshold 5 V

3 NPN Switching threshold 5 V,

or for Namur without ex protection

4 PNP Switching threshold 2.5 V

5 NPN Switching threshold 2.5 V

Advertising