Line 41

Function of batch counter

0 * Totalizer (counting process parallel to main counter)

1 Batch counter (automated counting process when reching P2)

Line 42

Multiplication Batch counter (only if line 41 = 1)

1 * Default

max. 999

Line 43

Actual value Correction (only if line 31 = 4)

0 * No correction value

max. 999999

Line 44

Display after power failure

0 * No indication of power failure

1 Indication of power failure (7-segment display blinks)

Line 51

Baud rate

0 * 4800 Baud

1 2400 Baud

2 1200 Baud

3 600 Baud

Line 52

Parity

0 * Even parity

(7 data bits)

1 Odd parity

(7 data bits)

2 No parity

(8 data bits)

Line 53

Stop bits

0 * 1 Stop bit

1 2 Stop bits

Line 54

Address

0 * from

99 to

Line 55

Assignment Output value via interface (line 31 = 5)

0 * Display value

1 XP

2 P1

3 P2

4 SC
5

Σ

6

7 SF

Line 56

RS422: Control contacts TxD+ and/or TxD

0 * Switched in sense of transmission when transmitting, in

sense of reception when receiving

1 Always in sense of transmission
The dash line indicates the end of the third programming field.
To leave the programming mode enter the key

.

Counter now reverts to the operating mode.