The dash line indicates the end of the first programming field.

Switch to programming field 2 with the

key.

Programming field 2

Here the individual operating parameters are blocked or released for

operator access.

„StAt“ appears in the display. The corresponding LED of the

chosen is blinking.

Meaning of the status numbers

0

The operating parameters can be selected, read and chan-

ged or deleted on the operator level. (free access)

1

The operating parameters can be selected and read on the

operator level. (display only)

2

Operating parameter is completely disabled for the operating

mode. If this operating parameter is selected it is not dis-

played on the operating mode but bypassed. The respective

function is retained. (disabled)

Change status ➜ Enter the corresponding status number with the keys

and

.

The changed status number is automatically saved when the next

programming line is selected with the

key.

Line 11

XP - Main counter (current counter status)

Line 12

P1 - Preset value 1

Line 13

P2 - Preset value 2

Line 14

SC - Start count

Line 15

Σ

- Totalizer

Line 16

- Time meter

Line 17

SF - Scaling factor

The dash line indicates the end of the second programming field.