Baumer NE218 Benutzerhandbuch

Seite 34

Advertising
background image

NE218

34

www.baumer.com

No code number is set at the factor, and therefore this code request

can be skipped by pressing the

key. The code is set in program-

ming line 40. After a code has been set, the programming level can

only be called by entering the correct code.

Incorrect code If an incorrect code has been input:

appears in the display when the

key is pressed.

After 15 seconds, the system will automatically revert to the

operating mode.

Press the

key.

Input the correct code.

Correct code unknown If the correct code is not known:

Return the counter to the factory.

Correct code ➜ When the correct code has been input, press the

key.

The programming segments are now called up in succession.

Programming field 1

Here all operating parameters can be selected and changed. The

operating parameters that are blocked for the operator are also dis-

played.

Press the

key again.

The operating parameters are now called up.

The respective LED flashes.

Line 1

XP - Main counter (current counter status)

Line 2

P1 - Preset value 1

Line 3

P2 - Preset value 2

Line 4

SC - Start count

Line 5

Σ

- Totalizer

Line 6

- Time meter

Line 7

SF - Scaling factor

Advertising