Line 29

Reset main counter (control input 1, terminal 11)

0 * Automatic reset and external, statically effective

1 Automatic reset and external, edge active

2

External static

3 External edge-triggered

4 External with “Start function“

Line 31

Function control input 2 (terminal 12)

0 * Stop

1 Hold

2 Keylock

3 Operating time meter counts/stops, counts as long as signal

present

4 Correction of actual value

5 Print (only for interface operation)

Line 33

Output logic

0 * Both outputs as normally open

1 P1 normally closed, P2 normally open

2 P1 normally open, P2 normally closed

3 Both outputs as normally closed

Line 35

Output time P1

0.01 Minimum signal duration

* 0.25 Default

99.99 Maximum signal duration

LAtCH = Latched signal (by pressing the

- key)

Line 36

Output time P2

0.01 Minimum signal duration

* 0.25 Default

99.99 Maximum signal duration

LAtCH = Latched signal (by pressing the

- key)

Line 37

Take-over preset P1, P2, SC

0 * Effective immediately

1 At reset

Line 38

Setting range P1, P2 and SC

0 * Only in positive counting range

1 In positive and negative counting range

Line 39

Assignment of function key F

0 * Without function

1 XP

2 P1

3 P2

4 SC
5

Σ

6

7 SF

Line 40

Code settings

0 * No code

max. 9999