5.2 Counting mode for main counter and totalizer (Input Modes)

Counting input track A
possiply set to up/down
signal on track B

Programming line 25 to digit 0.

Track A

Up/Down

Counting

Differential counting, track A
adding, track B subtracting
(A-B)

Any signal duration and time.

Programming line 25 to digit 1.

Track A

Track B

Counting

Totalizing, tracks A and B
adding (A+B)

Programming line 25 to digit 2.

n n-1 n-2 n-3 n-5 n-6 n-7

Track A

Track B

Counting add.

Up/down counting with two
counting signals,
phase-
offset by 90

o

.

The counting direction is

automatically identified from

the leading/lagging 90° phase

offset. The internal phase discri-

minator performs the necessa-

ry evaluation. One- , twofold or

fourfold evaluation is possible.

Programming line 25 to digit 3,

4 or 5.

Track A

Track B

Counting 4x

Counting 2x

Counting 1x

5.3 Output responses (output modes)
The behavior of the signal outputs is defined by the following set-

tings under the programming field 3:

Operating mode, reset mode, take-over of presets, output logic and
output time P1, P2 as momentary

or latched signal

.

The following diagrams illustrate some examples: