Baumer NE218 Benutzerhandbuch

Seite 41

Advertising
background image

NE218

www.baumer.com

41

Programming

adding

subtracting

Operating mode:

Line 22 to 0 = Progressive selection

Reset mode: Line 29 to 2

Without automatic reset

Achieved time P1, P2:

Line 35, 36 to momentary or latched

RESET

VW (P2)
VW (P1)
O (SC)

OUT P1

OUT P2

Addierende Betriebsart

RESET

SC
VW (P1)
VW (P2)

OUT P1

OUT P2

Subtrahierende Betriebsart

Operating mode:

Line 22 to 0 = Progressive selection

Reset mode: Line 29 to 0

With automatic reset

RESET

VW (P2)
VW (P1)
O (SC)

OUT P1

OUT P2

Addierende Betriebsart

RESET

SC
VW (P1)

VW (P2)

OUT P1

OUT P2

Subtrahierende Betriebsart

Operating mode:

Line 22 to 1 = Principal preselection

Reset mode: Line 29 to 0

With automatic reset

RESET

VW (P2)
VW (P1)
O

OUT P1

OUT P2

Addierende Betriebsart

RESET

VW (P2)
VW (P1)

O

OUT P1

OUT P2

SC

Subtrahierende Betriebsart

Operating mode:

Line 22 to 2 = Parallel comparison

Reset mode: Line 29 to 2

Without automatic reset

RESET

VW (P2)
VW (P1)
O

OUT P1

OUT P2

Addierende Betriebsart

Operating mode:

Line 22 to 3 = Trailing preselection

VW (P1) corresponds to the interval

between P1 and P2. When P2 is

changed, P1 is trailed.

RESET

VW (P2)
VW (P1)
O (SC)

OUT P1

OUT P2

Addierende Betriebsart

Operating mode:

Line 22 to 0 = Progressive selection

Reset mode: Line 29 to 4

Without automatic reset, external

RESET with Start function.

OUT P1 and OUT P2 are activated

via the external RESET and deactiva-

ted when preselection is reached.

VW (P2)

O (SC)

OUT P1

OUT P2

RESET

VW (P1)

Addierende Betriebsart

SC

VW (P2)

OUT P1

OUT P2

RESET

VW (P1)

Subtrahierende Betriebsart

Advertising