WIKA T32.xS Benutzerhandbuch
Seite 36

GB
11258421.10 08/2014 GB/D
36
WIKA operating instructions model T32.xS
10. Notes for mounting, operating in ...
10. Notes for mounting and operating in
hazardous areas
In hazardous areas, only use temperature transmitters that are
approved for those hazardous areas. The approval is marked on the
product label.
When connecting them to other devices or component, observe the
connection requirements regarding explosion protection, such as
maximum admissible voltage, power or load with capacitances (see
chapter 10.2 “Specific conditions for safe use”).
The following information is based mainly on the EC type examination
certificate, Certification No. BVS 08 ATEX E 019 X.
10.1 Model overview and their European approvals
Model
Ex protection and approval no. Ignition
protection type
T32.1S.0IS-x
(head
mounting
version)
II 1G Ex ia IIC T4/T5/T6 Ga
II 1D Ex ia IIIC T120 °C Da
intrinsically safe
equipment
T32.3S.0IS-x
(rail mounting
version)
II 2(1)G Ex ia [ia Ga] IIC T4/T5/T6 Gb
II 2(1)D Ex ia [ia Da] IIIC T120 °C Db
intrinsically safe
equipment
T32.xS.0NI
II 3G Ex nA IIC T4/T5/T6 Gc X
non-sparking
equipment
T32.1S.0IC-x
T32.3S.0IC-x
II 3G Ex ic IIC T4/T5/T6 Gc
intrinsically safe
equipment
The nominal electrical values for the head and the rail versions are
identical.
For T32.xS.0IS: The intrinsically safe sensor circuit (optional 2-wire,
3-wire or 4-wire configuration) for both versions is intended for the
supply of equipment in areas with 1G or 1D requirements.