WIKA operating instructions RTD and TC, intrinsically safe designs (Ex i)

3345267.12 01/2014 GB/D

5

GB

WARNING!

... indicates a potentially dangerous situation in a potentially explosive atmosphere,

resulting in serious injury or death, if not avoided.

WARNING!

... indicates a potentially dangerous situation, caused by hot surfaces or liquids, that

can result in burns if not avoided.

Abbreviations
RTD

Resistance Temperature Detector” = Resistance thermometers

TC

Thermocouple”

2. Safety

WARNING!

Before installation, commissioning and operation, ensure that the appropriate thermo-

meter has been selected in terms of measuring range, design and specific measuring

conditions.

Choose the thermowell with regard to the maximum pressure and temperature (e.g.

rating chart in DIN 43772).

Non-observance can result in serious injury and/or damage to equipment.

Further important safety instructions can be found in the individual chapters of these

operating instructions.

2.1 Intended use

These resistance thermometers and thermocouples are used for temperature measurement in

industrial applications, in hazardous areas.

Resistance thermometers are used for measuring temperatures from -200 ... +600 °C. For

thermocouples, the possible measuring ranges range from -200 ... +1,200 °C. Thermometers

of this design can be installed directly in the process as well as in thermowells. The thermowell

designs can be selected as desired, but the operating process data (temperature, pressure,

density and flow rate) must be taken into account.