-21-

GB

special pipe of 25 mm diameter that is

installed above the highest point of the

reservoir surface level.

- When filling the system with the medium

we must ensure that the suction piping and

the pump are filled with the medium and

all the air is bleed out. The stop valve from

the suction side, the inflow and outflow

pipes, and the stop valve for vacuum

equalising should all be opened, all the

while controlling the values of the medium

flow, and close the sealing lock fittings.

‘Dry’ operation (without medium) of the pump

is especially dangerous as it causes above
all wear of the mechanical seals of the pump.

B) Assembly of ECL additional parts

The frequency converter and pump on/off

switch, for ECL pumps with a separately in-

stalled regulator, should be installed on a wall

or in a suitable cabinet so that the cooling ribs

of the frequency converter are in a vertical

position, that the ambient temperature ranges

from 5°C to 40°C, that a sufficient circulation

of air is ensured, and that the electronics are

protected from dripping water. The regulator

and pump should be connected according to

the supplied wiring plan with a six-wire cable

of an appropriate cross-section, or with a four-

wire energy and a 2-wire signal cable (see

diagram in attachment).

Only qualified persons may programme

and install the regulation with a frequency

converter.

The frequency converter and pump electric

motor must always be earthed through the

earthing conductors that are connected at

the connecting clips.

C) Connecting the pump

Connection, operation, and usefulness of the

pump are dependent on the type of pump

overloading sensor used for regulating the

pump.

The pressure difference meter (meter P) is

used as a sensor.

When using the pressure difference meter

regulator, the pump components are

electrically connected according to the wiring

plan (shown in the attachment diagram).

The frequency converter contains a high

voltage when connected to a network. After

disconnecting the converter from an electric

charge, wait at least one minute before

continuing operation. When connecting or

disassembling external control signals to the

converter clips ensure that the converter is

not under power.

The mechanical connection of the frequency

converter should be done according to the

instructions of a professional with the crucial

consideration of the spacing to ensure

adequate ventilation.

It also necessary to consider the instructions

for connecting electric conductors. Special

attention should be given to the Cu conduc-

tor cross-section, so that the Cu conductor of

the electric motor is equal to the cross-section

of the conductor cable that connects the fre-

quency converter to the network. The electric

motor cable should be fastened separate from

the other cables. It is necessary to avoid long

parallel connections with the other cables.

5. s

tart

-

up

and

shut

-

dOwn

Of

the

puMp

A) Preparations for starting the pump

- The electrical connections must only be

made by a professional familiar with the

regulations and who is qualified for this

work. (Please refer to attachment!)).

- For three-phase electric motors, the elec-

trical connection must be implemented ac-

cording to the manufacturer’s instructions

and set to the switching time to 3 sec +- 30%

as recommended. With special configura-

tions of electric motors with anti-explosion

protection, increased security, or increased

temperature class, the connection must be

made through the safety switch.

- The direction of the pump electric motor

rotation must be the same as marked on

the pump parts. If the direction is opposite,

two phases on the electric cables must be

changed in the electric motor cabinet.

- The pump and piping system must have

the following points assured:

- a) It must be filled with the medium.

- b) The suction piping up to the pump

must have all the air bled out.

- c) All additional connections that prevent

the flow of medium past the pump

must be closed.