D) disruptions – IMP Pumps ECL Benutzerhandbuch

Seite 27

Advertising
background image

-27-

GB

D) Disruptions

Insufficient flow of pump

Overloading the electric motor

Excessive outflow pressure

Excessive temperature of bearings

Excessive temperature of pump

Insufficient level of medium

Release of medium on the shaft seal

Uneasy run of pump

Cause

Measures

X

Pump operation under

excessive pressure (open

system)

Setting of operational point

(Q, H)

X

Excessive back pressure

Increasing the number of

rotations

X

X

X

Air is not bled out of

pump, insufficiently filled

with medium

Bleed out the air and fill up the

system with medium

X

Blocked inflow into pipes

Remove deposits

X

Occurrence of air

cushion in the piping

system

Change pipes, install valve for

bleeding air

X

X

X

The pump is creating

resonant effects and

whirling in the piping

system

Checks connections to the piping

system and the fastening of the

pump; fasten the clamps on the

piping; install compensators into

the piping system

X

X

X

Insufficient NPSH of the

pump, excessive suction

height

Check the state of the medium;

open the lock in the inflow

pipe; change the inflow lead

in case of strong resistance;

check the suction opening

X

No centreline on shaft

Coordinate the settings of the

vanes

X

No voltage on connectors

(frequency converter or

motor)

Check connectors and start the

voltage supply

X

Information on the

error is on the frequency

converter display

Call an authorised servicer or

serving operator

X

Air suction on

mechanical seal

Change mechanical seal

X

Wrong direction of pump

rotation

Change 2 phases on the

incoming electrical connection

X

X

Operation on two phases

Change the fuse; check the

incoming connections

X

Damage to bearings

Change the bearings

X

X

X

Insufficient flow of

medium

Increase flow of medium

X

X

Wear of internal parts

Change internal parts

X

X

Back pressure of the

pump is lower than

expected

Setting of operational point

(Q, H)

X

Viscosity and thickness

of medium higher than

recommended

Consult with professional

personnel from the pump

manufacturer

X

Use of poor quality

materials

Change with high quality

materials

X

Fault on the sealing and

fixing screws

Change seals and tighten

screws

X

Seal on shaft is leaking

Change the seal

X

X

Damages on shaft and

seat of seal

Change the shaft and seals

Advertising