A) Pump malfunction:

Several types of protections are built into the

regulator, e.g. protection against increased

and reduced voltage, against increased

current, excessive ambient temperature

and similar. All these protections are set by

the factory to their optimal values. If one of

the protections stops the pump (e.g. loss of

electric power), the pump must be reset, that

is disconnected from the network, and then

restarted after several minutes.

If the repeated start does not work, or if the

pump frequently shuts down, a servicer must

be called, who will localise and remove the

error with the serving operator.

B) Electromagnetic compatibility and

unpleasant noise

As with all electronically regulated

devices, electronically regulated pumps

can also in specific circumstances

cause electromagnetic disturbances, are

electromagnetically disrupted, or cause

unpleasant noise. In most cases such

occurrences are easily overcome, e.g.

by changing the carrying frequencies

of the frequency converter, installing an

electromagnetic filter, and similar. In such

an event or similar case refer to a factory

expert or an authorised servicer to remove

the error.

C) Protection description
C1) UNDERVOLTAGE PROTECTION

If the direct voltage in the frequency

converter circuit falls under 65% of the

voltage circuit given value, the undervoltage

protection will start operating. The operation

of the undervoltage protection can be read

by the error number on the display.

Possible causes are:

- Loss of voltage supply. Removing error:

activate RESET after restarting the power

supply.

- Loss of one or two phases of the voltage

supply. Removing error: connect the

temporarily plugged out conductors and

activate RESET.

- Damages to elements in the direct circuit.

Removing error: Call a servicer.

C2) OVERVOLTAGE PROTECTION

If the direct voltage in the frequency

converter circuit increases above 45% of the

voltage circuit given value, the overvoltage

protection will start operating. The operation

of the overvoltage protection can be read by

the error number on the display.

Possible causes are:

- Increase of voltage supply. Removing

error: activate RESET after stabilising

network voltage to given.

- Insufficient time of stopping. Removing

error: programme the time of stopping and

activate RESET.

- Insufficient time of cancelling. Removing

error: programme the time of cancelling

and activate RESET.

- Insufficient time of braking. Removing

error: programme the time of braking and

activate RESET.

C3) OVERLOAD PROTECTION

Overload protection starts operating if the

converter current rises suddenly to more

than twice the given current value. The

operation of the overload protection can be

read by the error number on the display.

Possible causes are:

- In the electric motor coil. Removing error:

repairing the electric motor.

- Short-circuit in the cable leading to the

electric motor. Removing error: check and

replace the cable.

- Insufficient time of stopping. Removing

error: programme the time of stopping and

activate RESET.

- Insufficient time of starting. Removing

error: programme the start-up time and

activate RESET.

- Initial voltage of the U/f characteristic

too low. Removing error: programme the

initial voltage of the U/f characteristic and

activate RESET.

C4) IMPROPER EARtHING

The protection for improper earthing can be

read by the error number on the display.

Possible causes are:

- Improper earthing in the electric motor coil.

Removing error: repair the electric motor.

- Improper earthing in the electric motor

cables. Removing error: check and replace

the cable.