12

lfm, liquid flow meter

6.1.2.

The actual flow-rate value supplied by the integrated
sensor is available as an output, via a standard signal or
field bus.

english

13

Technical daTa

7.

Caution!

Risk of injury from pressure and discharge of fluid.
Important device-specific technical data is indicated on
the rating plate and the calibration plate

Observe permitted fluid according to rating plate

•

(depending on seal material).
Observe permitted pressure range on the calibration

•

plate of the device.

in

7.1.

scription on the rating plate

8719 LFC WASSER

M

a

d

e

in

G

e

rm

a

ny

00202378

W1XLP

24V DC 0-10V FKM

6,0 l/h

S/N 1006

Type

Brief description of the device
Operating fluid

Final value (Q

nom

) and unit

Power supply voltage, actual
value

Seal material

Serial number

Bar code
Identification number of the device

CE identification

Example:

english

14

inscription of the calibration

7.2.

plate

Calibration

Date

28. 01. 2009

Pressure

2,0 bar

Horizontal mounting position

Calibration date

Calibration pressure

Installation position

Example:

operating conditions

7.3.

Warning!

Risk of injury from malfunction due to effects of
weather!
The LFC / LFM is not designed for unrestricted use
outdoors.
If the device is not protected from the elements, there is
a risk of injury from the device failing.

Protect the device from direct sunlight.

•

Ensure that the ambient temperature permitted for the

•

device is observed.
Protect the device from humidity in consideration of

•

the protection class indicated below.

english

15

Allowable temperatures

Ambient temperature:

Operation: 0 – +55 °C
Storage: -10 – +70 °C

Fluid temperature:

+10 ... +40 °C

Permitted air humidity:

0 ... 95 %, without condensation

Operating fluids:

clean and low-viscosity liquids

Protection class in
accordance with
DIN EN 60529:

Types 8709 and 8719: IP65
(only if cables, plugs and sockets
have been connected correctly)

Type 8708 and 8718: IP40

conformity with the following

7.4.

standards

CE mark conforms to EMC Directive 2004/108/EEC (pre-
viously: 89/336/EEC)
(only if cables, plugs and sockets have been connected
correctly)

english

Type 8708, 8709, 8718, 8719

Advertising