Design and function – WIKA TR25 Benutzerhandbuch

Seite 11

Advertising
background image

WIKA operating instructions model TR25 (Ex i)

14073045.01 10/2013 GB/D

11

GB

4.2 Dimensions in mm

Version with clamp connection

4. Design and function

L

Connection head
Terminal block,

transmitter (option)
Tubular body

Ø D

i

Ø D

14053685.01

Legend:

M

Neck tube length

N(M

H

) Neck length

L

Insertion length

Ø D

i

Inner diameter of tube

Ø D

Clamp fitting

14027661.01

DN For pipe

Dimensions in mm PN

1) 2)
3)

External Ø x

Wall thickness Ø D

i

L

Ø D

8

13.5 x 1.6

10.3

71

25.0

40

10

17.2 x 1.6

14.0

71

25.0

40

15

21.3 x 1.6

18.1

71

34.0

40

20

26.9 x 1.6

23.7

71

50.5

40

25

33.7 x 2

29.7

71

50.5

40

32

42.4 x 2

38.4

71

50.5

40

40

48.3 x 2

44.3

71

64.0

25

DN For pipe

Dimensions in mm PN

1) 2)
3)

External Ø x

Wall thickness Ø D

i

L

Ø D

10

13 x 1.5

10

71

34

40

15

19 x 1.5

16

71

34

40

20

23 x 1.5

20

71

34

40

25

28 x 1

26

71

50.5

40

32

34 x 1

32

71

50.5

40

40

40 x 1

38

71

50.5

40

50

52 x 1

50

71

64.0

25

DN For pipe

Dimensions in mm PN

1) 2)
3)

External Ø x

Wall thickness Ø D

i

L

Ø D

¾"

19.05 x 1.65

15.75 71

25

40

1"

25.4 x 1.65

22.1

71

50.5

40

1 ½" 38.1 x 1.65

34.8

71

50.5

40

2"

50.8 x 1.65

47.5

71

64.0

25

DN For pipe

Dimensions in mm PN

1) 2)
3)

External Ø x

Wall thickness Ø D

i

L

Ø D

½"

12.7 x 1.6

9.5

71

25.0

40

¾"

19.05 x 1.6

15.85 71

25.0

40

1"

25.4 x 1.6

22.2

71

50.5

40

1 ½" 38.1 x 1.6

34.9

71

50.5

40

2"

50.8 x 1.6

47.6

71

64.0

25

Clamp per DIN 32676 for pipes per

DIN 11866 row B (ISO 1127)

Tri-clamp for pipes per BS4825 part 3 and

O.D.-tube

Clamp per DIN 32676 for pipes per

DIN 11866 row C (ASME BPE)

Clamp per DIN 32676 for pipes per

DIN 11866, row A

1) For maximum pressure range consider pressure rating of clamp.

2) Maximum operating temperature 150 °C

3) All thermowells of this model series which are exposed to internal pressure and have a nominal diameter (DN) of > 25 mm are

manufactured and tested in accordance with module H of the pressure equipment directive 97/23/EC.

Advertising