WIKA TR25 Benutzerhandbuch

Seite 20

Advertising
background image

14073045.01 10/2013 GB/D

20

WIKA operating instructions model TR25 (Ex i)

GB

7.4.2 Possible installation methods with the marking II 1/2 Ex ib IIC T6 Ga/Gb or

II 1/2 D Ex ib IIIC T65 °C Da/Db

The sensor or thermowell tip protrudes into Zone 0. The housing or connection head is in Zone 1

(Zone 21) or Zone 2 (Zone 22). It is sufficient to use an Ex ib type circuit.

Zone separation is guaranteed if sufficiently-tight (IP 67) process connections are used.

Examples of suitable process connections include gas-tight standardised industrial flanges,

threaded connections or pipe connections.

The welded parts, process connections, compression fittings, thermowells or housings used

must be designed such that they withstand all influencing variables resulting from the process,

such as temperature, flow forces, pressure, corrosion, vibration and impacts.

Zones 1, 2 or

Zones 21, 22

Hazardous area

Safe area

Thermowell

Thermowell

welded

TWxx

TWxx

Process

connection

Connection head/

Field housing

Tx10-B
Tx10-C

Tx10-C
Tx10-D

Tx10-H

Tx10-H

Option:

with built-in

transmitter:

e.g. T32

Tx10-A

Process

connection

Compression

fitting

Associated

electrical equipment

Intrinsically

safe supply or

suitable barrier

Intrinsically

safe supply or

suitable barrier

Intrinsically

safe supply or

suitable barrier

Intrinsically

safe supply or

suitable barrier

Tx10-A

Tx10-A

Tx10-A

Zones 0, 1, 2 or

Zones 20, 21, 22

7. Information on mounting and operation in hazardous areas