Design and function, Dn for pipe dimensions in mm pn, Version with threaded connection – WIKA TR25 Benutzerhandbuch
Seite 12: Thread neumo bioconnect

14073045.01 10/2013 GB/D
12
WIKA operating instructions model TR25 (Ex i)
GB
DN For pipe
Dimensions in mm
PN
2)
3)
External Ø x
Wall thickness Ø D
i
Ø G
LG L
10 13 x 1.5
10
Rd 28 x ⅛ 84 76 40
15 19 x 1.5
16
Rd 34 x ⅛ 84 76 40
20 23 x 1.5
20
Rd 44 x
1
/
6
84 72 40
25 29 x 1.5
26
Rd 52 x
1
/
6
84 70 40
32 35 x 1.5
32
Rd 58 x
1
/
6
84 70 40
40 41 x 1.5
38
Rd 65 x
1
/
6
84 70 40
50 53 x 1.5
50
Rd 78 x
1
/
6
84 70 25
65 70 x 2
66
Rd 95 x
1
/
6
88 72 25
Threads per DIN 11851
■
Version with threaded connection
14073164.01
Tube inner Ø Di
Thr
ead Ø G
Insertion length L
Overall length LG
DN For pipe
Dimensions in mm
PN
2)
3)
External Ø x
Wall thickness Ø D
i
Ø G
LG L
10 13 x 1.5
10
Rd 28 x ⅛ 84 76 40
15 19 x 1.5
16
Rd 34 x ⅛ 84 76 40
20 23 x 1.5
20
Rd 44 x
1
/
6
84 74 40
25 29 x 1.5
26
Rd 52 x
1
/
6
84 72 40
32 35 x 1.5
32
Rd 58 x
1
/
6
84 70 40
40 41 x 1.5
38
Rd 65 x
1
/
6
84 70 40
50 53 x 1.5
50
Rd 78 x
1
/
6
84 70 25
65 70 x 2
66
Rd 95 x
1
/
6
88 72 25
Thread per DIN 11864-1 Form A for pipes
DIN 11866 row A
14073164.01
Tube inner
Ø Di
Thr
ead Ø G
Insertion length L
Overall length LG
Flange connections, clamp connections and further nominal widths per DIN 11864 on request.
DN For pipe
Dimensions in mm PN
2) 3)
External Ø x
Wall thickness Ø D
i
Ø G
L
15
21.3 x 1.6
18.1 M30 x 1.5 84
40
20
26.9 x 1.6
23.7 M36 x 2
84
40
25
33.7 x 2
29.7 M42 x 2
84
40
32
42.4 x 2
38.4 M52 x 2
84
40
40
48.3 x 2
44.3 M56 x 2
84
25
50
60.3 x 2
56.3 M86 x 2
84
25
65
76.1 x 2.3
71.5 M90 x 3
88
16
Thread NEUMO BioConnect
®
for pipes per DIN 11866 row B (ISO 1127)
DN For pipe
Dimensions in mm PN
2) 3)
External Ø x
Wall thickness Ø D
i
Ø G
L
15
19 x 1.5
16
M30 x 1.5 84
40
20
23 x 1.5
20
M36 x 2
84
40
25
29 x 1.5
26
M42 x 2
84
40
32
35 x 1.5
32
M52 x 2
84
40
40
41 x 1.5
38
M56 x 2
84
40
50
53 x 1.5
50
M86 x 2
84
25
65
70 x 2
66
M90 x 3
88
25
Thread NEUMO BioConnect
®
for pipes per DIN 11866 row A
Thread NEUMO BioConnect
®
Thr
ead Ø G
Insertion length L
14073164.01
Tube inner Ø Di
2) Maximum operating temperature 150 °C
3) All thermowells of this model series which are exposed to
internal pressure and have a nominal diameter (DN) of > 25 mm
are manufactured and tested in accordance with module H of the
pressure equipment directive 97/23/EC.