Powering Up Your Vanguard 6435/6455

4-3

Power Up Sequence

Power Up Sequence

Introduction

One of two processes occur when you power up the Vanguard 6435/6455:

• The Vanguard 6435/6455 coldloads the operating software (Applications

Ware) and then initiates a node boot.

• The Vanguard 6435/6455 initiates a node boot using previously loaded

operating software (Applications Ware).

During the software loading and boot process, a series of messages appear on the
front panel display. These message sequences are described below. If something
other than these messages appear, or if the message ERR: Bad FLASH appears, a
problem has been encountered.

For a description of all the front panel messages, refer to the “Front Panel Display
Messages” section on page 4-6
.

Coldloading the
Software

This table shows the sequence of LCD messages that appear when a Vanguard
6435/6455 is coldloading the software:

Note

If the Vanguard 6435/6455 unexpectedly stops loading, it does not lock up.
Instead, it restarts the load cycle from the beginning.

Step

Display Message

1

BootPROM Vnn

2

Need Coldload

3

Erasing FLASH

4

Send FLASH Image

5

Writing to FLASH

6

Coldload Done

7

BootPROM Vnn

8

Loading FIPL

9

Loading FBIST

10

Testing Node

11

BootPROM Vnn

12

Loading FIPL

13

Loading ONS

14

Booting ONS

15

BootPROM Vnn

16

--- Node Up ---

Note: nn is the version number.