2-32

Hardware Description

Vanguard 6455 Option Cards

E1 Card Impedance
Jumper Settings

These jumpers reside behind the BNC connectors on the VoIP Convergence Card
(see Figure 2-36 and Figure 2-43). Use these jumpers to ground the Tx ring and/or
the Rx ring on the BNC connectors. these jumpers control the BNC pair directly in
front of them. This table details the jumpers’ use:

Description

Use

Jumper Configuration

The terminals are
balanced and are not
grounded.

Note

For 120

twisted pair

applications, all jumper
shunts must be removed
from the pins to provide
at least 2.5mm clearance
between network lines
(TRing and Rring) and
ground.

This jumper
configuration is
required to connect a
balanced 120

twisted pair E1
network.

Note

This is the only
configuration for
120

impedance

setting.

The TRing (the coax
shield for the Tx pair) is
grounded directly.

The Rring (the coax
shield for the Rx pair) is
not grounded.

This jumper
configuration is
normally used to
connect an
unbalanced 75

coax

to BNC connectors on
an E1 network.

The TRing (the coax
shield for the Tx pair) is
not grounded.

The Rring (the coax
shield for the Rx pair) is
grounded directly.

This configuration
may be used with
certain unbalanced
75

coax E1

networks.

Note

Use this configuration
only if the network
provider requests it.
The ITU requires this
setting.

Rx

Tx

Rx

Tx

Rx

Tx