Vanguard Managed Solutions Vanguard 6435 Benutzerhandbuch

Seite 80

Advertising
background image

3-12

Installation and Replacement

Installing The Vanguard 6435/6455

Ports 3 and 4
These ports have RJ-45 connectors. Use Port 4 as the CTP because Port 3 cannot be
used for coldloading software to the node. Figure 3-6 shows the pin numbers for
ports 3 and 4.

Figure 3-6. Ports 3/4 Pin Numbers

18

RXCB

OUT

IN

20

DTR

IN

OUT

21

TXCB

OUT

IN

22

ETXCB

IN

OUT

24

ETXCA

IN

OUT

25 (V.36 only)

TM

NC

IN

DB25 V.35/V.36 Pinouts (continued)

Pin

Signal

DCE Position

DTE Position

DB25 V.11/X.21 Pinouts

Pin

Signal

DCE Position

DTE Position

1

GND

-------

-------

2

TXDA

IN

OUT

3

RXDA

OUT

IN

4

RTSA

IN

OUT

6

DCDB

OUT

IN

7

SIGGND

-------

-------

8

DCDA

OUT

IN

14

TXDB

IN

OUT

15

TXCA

OUT

IN

16

RXDB

OUT

IN

20

RTSB

IN

OUT

21

TXCB

OUT

IN

22

ETXCB

IN

OUT

24

ETXCA

IN

OUT