English o, Port information for type 4040 – Burkert Type 4040 Benutzerhandbuch
Seite 11

4040 - 9
english
O
PERATION
Port Information for Type 4040
Pin
C
F
1
24V DC OUT
Binary inputs:
Buffer_full, + 24 V
Start/Stop,
Reset alarm,
Key-operated switch,
Lock_max_alarm,
Sealing_air_alarm, PE
2
GND
GND
3
+24V DC
4
5
6
IN 24V
Lock_max_alarm (0 V / 24 V)
PIA 01
7
IN 24V
Buffer_full (0 V / 24 V)
LIA 01
8
IN 24V
Sealing_air_alarm (0 V / 24 V)
PIA 02
9
IN 24V
10
IN 24V
Start/Stop (0 V / 24 V)
11
IN 24V
Empty run (0 V / 24 V)
12
IN 24V
Reset alarm (0 V / 24 V)
13
IN 24V
Key-operated switch (0 V / 24 V)
Pin
A
B
1
24V DC IN
+ 24 V - Supply for binary outputs:
Connect to F3
24V DC OUT
Supply for transmitter:
Actual_temperature T,
Conveying pressure p, + 24 V
Main pressure p1,
Supply for positioner, + 24 V
2
OUT 24V
Sealing air
XOV 01
GND
Positioner (4-20 mA) GND
Positioner -
Conveying pressure p (4-20 mA) GND
3
OUT 24V
Lock_IN
Motor 01
4
OUT 24V
Alarm (red)
5
OUT 24V
Standby (green)
Out 4-20 mA
Target control value lift,
Positioner (4-20 mA) +
6
GND
GND for binary outputs
Out 4-20 mA
Conveying pressure p (pressure trans-
mitter signal)
7
OUT 24V
Conveyance (white)
8
9
10
11
IN 4-20 mA
Actual_temperature T, output from
temperature transmitter (4-20 mA)
12
IN 4-20 mA
Conveying pressure p, output from
pressure transmitter (4-20 mA)
13
IN 4-20 mA
Main pressure p1, output from
pressure transmitter (4-20 mA)