Definitions and Abbreviations of the Values Used
Abbreviation
Display
(6 characters
maximum)
Description
In module
Meaning
Default value
Value
range
Unit
Recipe datum
Process datum
Parameter datum
Calibration datum
t1
t1
Pause: settling time after
start
AUTO conveyance
Time after vE has been
reached after start
15 10-100 s
yes
t2
t2
Time out: no conveying of
materials
AUTO conveyance
If pressure remains below
pmin for this period, the
system assumes that there
is no flow of materials
20 10-100 s
yes
t3
t3
Time out: system blocked
at lock
IN
AUTO conveyance
If pressure exceeds pmax
for this period, the system
assumes that the pipes are
blocked
10 5-100
s
yes
t4
t4
Pause: settling time at
lock
STOP due to blockage
AUTO conveyance
After this period, the lock is
opened again
10 5-100
s
yes
t5
t5
Time out: system blocked
at lock
STOP due to blockage
AUTO conveyance
If the system is blocked for
this period, there will be
an alarm
20 5-100
s
yes
t6
t6
Time out: check
Buffer FULL
AUTO conveyance
If the signal Buffer FULL
appears for this period,
Buffer FULL is accepted
10 5-100
s
yes
t7
t7
Pause: settling time for
lock
STOP because buffer
FULL
AUTO conveyance
After this period, the lock is
opened again
10 5-100
s
yes
t8
t8
Time out: system blocked
at lock
STOP because buffer
FULL
AUTO conveyance
If the buffer is full for this
period, there will be an
alarm
10 5-100
s
yes
t12
t12
Time out: system blocked
at lock
STOP
STOP without empty
run
Due to closed lock and
blockage
60 5-100
s
yes
t13
t13
Time out: no material
STOP without empty
run
If pressure remains under
pmin for this period, the
system assumes there is
no flow of materials
60 5-100
s
yes
t16
t16
Time out: system blocked
at lock
STOP
STOP with empty run
Due to closed lock and
blockage
60 5-100
s
yes
t17
t17
Time out: no material
STOP with empty run
If the pressure remains
below pmin for this period,
the system assumes there
is no flow of materials
60 5-100
s
yes
T2
Default_Temp Actual temperature (ma-
nual entry)
AUTO conveyance
STOP without empty
run
STOP with empty run
Manually entered value for
the calculation of Q or v
is necessary if there is no
measured value available
0
0-160
°C
yes
QLP
QLP
Leakage air quantity
(operations)
AUTO conveyance
Offset by lock leakage at
various pressures (con-
veying pressure)
0
0-3000 m3/h
yes
QLPN
QLPN
Leakage air quantity
(standard)
AUTO conveyance
Offset by lock leakage at
various pressures (con-
veying pressure)
0
0-3000 Nm3/h
O
PERATION