Burkert Type 4040 Benutzerhandbuch
Seite 24

22 - 4040
english
Definitions and Abbreviations of Values Used
- Process data can be displayed during normal operations.
- Configuration data (data pertaining to the system):
==> System is OFF
==> Include recipe and calibration data
- Parameter data (data pertaining to the control loop): ==> System ON/OFF
The data areas must be stored contiguously (stop and start word)
Abbrevia-
tion
Display
(6 charac-
ters maxi-
mum)
Description
In module
Meaning
Default value
Value range
Unit
Recipe datum
Process datum
Parameter datum
Calibration datum
Recipe_no. Rec. no
Number of recipe
Enter recipe
1
1-9
yes
Product
Product
Product to be
conveyed
Enter recipe
Designation of the product
as text
-
16 characters
yes
Feed_way
Feed_way Conveying line
Enter recipe
Designation of the con-
veying line as text
-
16 characters
yes
Lock
Lock
Name of the lock
Enter recipe
Designation of the lock
as text
-
16 characters
yes
Empty_run
Empty run
Stop with or
without empty run
Enter recipe
Differentiation: with or
without empty run
0
0: without e.r.
1: with e.r.
yes
vE
vE
Speed in con-
veying line
AUTO conveyance
Target conveying speed
after lock
0
0-40.0
m/s yes
vL
vL
Empty-run speed
STOP with empty run
Target speed during empty
run
0
0-40.0
m/s yes
tvE
tvE
Time needed to
reach vE
AUTO conveyance
for start function
v0=(vE/tvE)*t
30 1-30
s
yes
tvL
tvL
Time needed to
reach vL
STOP with empty run
for empty-run function
v0= vE + (vL-vE)/tvL*t,
0<t<tvL
30 1-30
s
yes
pmin
pmin
min. conveying
pressure
AUTO conveyance
STOP without empty run
STOP with empty run
lowest permissable con-
veying pressure during
media conveyance
0
0-10.00
bar yes
pmax
pmax
max. conveying
pressure
AUTO conveyance
STOP without empty run
STOP with empty run
highest permissable
conveying pressure during
media conveyance
6
0-10.00
bar yes
D
D
Diameter of pipe
before and after
lock
AUTO conveyance
STOP without empty run
STOP with empty run
for the calculation of Q or v 50 5-355
mm yes
O
PERATION