If it is not possible to place the object in the nominal measuring range, please be aware that with
deviations of less than

±

10% of the nominal measuring distance, the sensor works at its best.



The correct size of the reflective tape can be calculated as follows:














Remark:

-

The angle of the reflector against the sensor axes must be within

±

15°.

-

In some application it could happen to mount a shorter reflective tape as the measuring range.
Never mind as long as you choose a mode, so that the output current is changing when the ob-
ject is moving. For such cases it is also possible to optimize the measuring range with the
teach-in procedure.

1.2 x nominal measuring range x distance to reflector

length =

nominal measuring distance


recommended width:
measuring distance

50 mm

5 mm

measuring distance

150 mm

20 mm

measuring distance

350 mm

35 mm

measuring distance

1400 mm

50 mm