Baumer BA ZADM023 Benutzerhandbuch
Seite 79
Seite / Page 79
Status request, meaning of the bytes
Byte Nr.
meaning
comment
1+ 2
HW/SW version
3 + 4
First active pixel
Can not be changed by the user
5 + 6
Last active pixel
Can not be changed by the user
7 + 8
Hi-Byte of threshold level 1
9 + 10
Low-Byte of threshold level 1
11 + 12
Hi-Byte of threshold level 2
13 + 14
Low-Byte of threshold level 2
15 + 16
Duration of exposure
As long as this value is below max. exposure time the sensor is not
soiled
17 + 18
Type of measurement
This two bytes represent the actual type of measurement
Bit 0: Sensor stays in programming mode
Bit 1: Sensor stays in SET-Mode
Bit 3: left edge
Bit 4: right edge
Bit 5: center position
Bit 6: width / distance edges
Bit 7: width / sum of objects
Example:
Sensor sends ASCII-Code 0x30 0x38, = hexadecimal number
0x08 or binary 0000’1000
left edge
19 + 20
Internal parameter
Factory use only
21 + 22
Internal parameter
Factory use only
23 + 24
Max. exposure value
Factory set
If the value “duration of exposure” reach this limit, the alarm output
is set.
25 + 26
Internal parameter
Factory use only