Status request, meaning of the bytes

Byte Nr.

meaning

comment

1+ 2

HW/SW version

3 + 4

First active pixel

Can not be changed by the user

5 + 6

Last active pixel

Can not be changed by the user

7 + 8

Hi-Byte of threshold level 1

9 + 10

Low-Byte of threshold level 1

11 + 12

Hi-Byte of threshold level 2

13 + 14

Low-Byte of threshold level 2

15 + 16

Duration of exposure

As long as this value is below max. exposure time the sensor is not
soiled

17 + 18

Type of measurement

This two bytes represent the actual type of measurement
Bit 0: Sensor stays in programming mode
Bit 1: Sensor stays in SET-Mode
Bit 3: left edge
Bit 4: right edge
Bit 5: center position
Bit 6: width / distance edges
Bit 7: width / sum of objects
Example:
Sensor sends ASCII-Code 0x30 0x38, = hexadecimal number
0x08 or binary 0000’1000

left edge

19 + 20

Internal parameter

Factory use only

21 + 22

Internal parameter

Factory use only

23 + 24

Max. exposure value

Factory set
If the value “duration of exposure” reach this limit, the alarm output
is set.

25 + 26

Internal parameter

Factory use only