8teaching the switching output – Baumer BA ZADM023 Benutzerhandbuch

Seite 65

Advertising
background image

Seite / Page 65

8

Teaching the switching output

It is possible to set two threshold values inside the analog value of 4 – 20 mA.
Depending upon the values programmed into the switching output, and the status of the actual
measured value, the switching output will either be High or Low.



For teaching the threshold value, it is necessary to simulate the tolerance position of the object or
the tolerance size of the object.


One switching output procedure:









SET

min. 2 sec
< 5 sec

TEACH

“TEACH“ LED is blinking slowly

place an object, which repre-

sents the first tolerance value

SET

TEACH

“TEACH“ LED blinks fast for a

short time

place an object, which represents

the second tolerance value

SET

TEACH

“TEACH“ LED blinks fast for a

short time

the two thresholds are taught