Baumer BA ZADM023 Benutzerhandbuch
Seite 80
Seite / Page 80
12.4 Examples
Sensor 5, set type of measurement to center position
Master sends
Transmitted bytes in hexadecimal
Sensor sends
ENQ ‘5’
0x05 0x35
0x06
ACK
STX ‘B3’ ETX
0x02 0x42 0x33 0x03
Sensor 2, data request (actual value 416 or 0x01A0)
Master sends
Transmitted bytes in hexadecimal
Sensor sends
ENQ ‘2’
0x05 0x32
0x06
ACK
STX ‘A’ ETX
0x02 0x41 0x03
0x05 0x32
ENQ ‘2‘
ACK
0x06
0x02 0x30 0x31 0x41 0x30 0x03
STX ‘01A0’ ETX
Sensor 7, set thresholds to 498 and 517, logic of the switching output (the switching output is ON if the measured value is
between threshold 1 and threshold 2, otherwise OFF).
Master sends
Transmitted bytes in hexadecimal
Sensor sends
ENQ ‘7’
0x05 0x37
0x06
ACK
STX ‘F1F2205’ ETX
0x02 0x46 0x31 0x46 0x32 0x32 0x30 0x35
0x03