Baumer BA ZADM023 Benutzerhandbuch

Seite 80

Advertising
background image

Seite / Page 80

12.4 Examples

Sensor 5, set type of measurement to center position

Master sends

Transmitted bytes in hexadecimal

Sensor sends

ENQ ‘5’

0x05 0x35

0x06

ACK

STX ‘B3’ ETX

0x02 0x42 0x33 0x03



Sensor 2, data request (actual value 416 or 0x01A0)

Master sends

Transmitted bytes in hexadecimal

Sensor sends

ENQ ‘2’

0x05 0x32

0x06

ACK

STX ‘A’ ETX

0x02 0x41 0x03

0x05 0x32

ENQ ‘2‘

ACK

0x06

0x02 0x30 0x31 0x41 0x30 0x03

STX ‘01A0’ ETX



Sensor 7, set thresholds to 498 and 517, logic of the switching output (the switching output is ON if the measured value is
between threshold 1 and threshold 2, otherwise OFF).

Master sends

Transmitted bytes in hexadecimal

Sensor sends

ENQ ‘7’

0x05 0x37

0x06

ACK

STX ‘F1F2205’ ETX

0x02 0x46 0x31 0x46 0x32 0x32 0x30 0x35
0x03

Advertising