Baumer BA ZADM023 Benutzerhandbuch
Seite 66
Seite / Page 66
Two switching outputs procedure:
Logic of the switching output (one switching output)
If threshold 1 < threshold 2; the switching output is ON if the measured value is between threshold
1 and threshold 2, otherwise OFF
If threshold 1
>
threshold 2; the switching output is OFF if the measured value is between thresh-
old 1 and threshold 2, otherwise ON
Logic of the switching output (two switching outputs)
If measured value > threshold 1; the switching output S1 is ON, otherwise OFF
If measured value > threshold 2; the switching output S2 is ON, otherwise OFF
SET
min. 2 sec
< 5 sec
S1 S2
“S1“ LED is blinking slowly
place an object, which represent
the first tolerance value
SET
“S1“ LED blinks fast for a s hort
time, “S2“ is blinking
place an object, which represent
the second tolerance value
SET
“S2“ LED blinks fast for a short
time
the two thresholds are taught
S1 S2
S1 S2