6 technical data – TechniSat TechniRouter 9/2x4 G Benutzerhandbuch

Seite 42

Advertising
background image

42

EN

6 Technical Data

TechniRouter

9 / 1x8 G

9 / 1x8 K

9 / 2x4 G

9 / 2x4 K

Article number

0000/ 3294

0000/ 3295

0000/3296

0000/3297

Return path, terrestrial:

5..790 MHz

Satellite:

950...2150 MHz

RP /

Terr.

Sat.

RP /

Terr.

Sat.

RP /

Terr.

Sat.

RP /

Terr.

Sat.

Number of trunk inputs

1

8

1

8

1

8

1

8

Number of trunk outputs

1

8

1

8

Number of subscriber cables

1

1

2

2

Subscriber per cable

maximum 8

maximum 8

maximum 4

maximum 4

Subscriber number and
receiving channels

(User bands)

channel 1:

1284 MHz

channel

2:

1400 MHz

channel 3:

1516 MHz

channel 4:

1632 MHz

channel 5:

1748 MHz

channel 6:

1864 MHz

channel 7:

1980 MHz

channel 8:

2096 MHz

channel 1 :

1284 MHz

channel 2:

1400 MHz

channel 3:

1516 MHz

channel 4:

1632 MHz

Trunk loss

2...3

1)

dB

3 ... 5

dB

2...3

dB

3...5

dB

Gain

of the subscriber signals

-1 dB

13...18

dB

-8 dB

13...18

dB

-5 dB

17...22

dB

-12

dB

17...22

dB

Reflection loss

10 dB

Isolation

Trunks

Subscriber

45 dB

2)

30 dB

Input level,

satellite signal

recommended

70 dBµV

minimum

(

=

ˆ

sensitivity)

40 ... 35 dBµV, although the subscriber cables, depending on length,

must be supplied with far higher levels.

maximum

80 dBµV

3)

Phase noise

-60 dBc/Hz (SSB @ ∆f = 1 kHz from the carrier )

Power supply

for

devices

From the receivers

for LNBs

At the base unit, 230V / 18 V, 800 mA,

short circuit and overload protected

Power
requirement

in
operation

Maximum 4 W / 270 mA from the receiver, ∅7.5 W from the power supply

Standby

0 W from the receiver, 0.1 W from the power supply (single basic unit)

with two LNBs
(per 200 mA)

p.a.

Depending on TV habits, Benchmark

18 kWh

(single base unit)

Control

by the receiver

DiSEqC-Protocol as per to EN 50494

=

ˆ

Unicable, OLT, SCR or SCD

Special features

Each receiving channel can be protected by a PIN-Code, automatic power

save feature, traffic indicator = installation aid

Screening attenuation

In accordance with EN 50083-2 (TechniSelect S)

Environmental conditions

-25...+55°C, Surge protection at inputs and outputs: < 5 kV, IP 50

Accessories

deployable in the trunk

Intermediate amplifier 9Z, (double) tap 9/2A, passive distributor 9P

deployable in the subscriber

line

Intermediate amplifier 1Z (broadband, remote-fed), attenuator, distributor,

loop through sockets with 10 dB, 13 dB or 20 dB tap loss, terminal sockets

Dimensions:

l x

w x h,

weight

G:

290 x 114 x 43 (mm); 0.5 kg

K:

216 x 123 x 43 (mm); 0.36 kg

1)

Values at the lower ... upper band limits

2)

All other trunk and subscriber lines with signal

3)

Conforming to EN 50083-3: namely IMA3 at the output: 35 dB

Advertising
Dieses Handbuch ist für die folgenden Produkte bezogen werden: