Reset button
The Reset button is placed between the Identification LED and the RS 485 interface on
the front panel of the central module.
This button allows you to reset the default settings and disable the netfilter rules.
Resetting the default settings
Pressing and holding the button during the booting process resets the default settings
of the central module.
How to reset the default settings of the central module:
1. Turn off both power packs of the central module.
2. Press and hold the Reset button on the front panel of the device.
3. Keep the button pressed and turn the device on.
4. Release the button when the green Switch-LED starts blinking.
NOTE:
To prevent you from pressing the button by accident, you are required to
use a thin, pointed object for pressing the button.
NOTE:
After the function has been carried out, the default settings of the central
module do apply again. However, the configured assignment of the Dynamic Ports
and the purchased premium functions remain unaltered.
NOTE:
You can also use the Config Panel web application to reset the default settings.