Specifications – WIKA T12 Benutzerhandbuch
Seite 13

GB
3211517.07
07/2010
GB/D
WIKA operating instructions temperature transmitter T12
13
3. Specifications
Specifications
Model T12.10.xxx Model T12.30.xxx
Ambient/storage
temperature
■
Standard range
■
Extended range
-40 ... +85 °C
-50 ... +85 °C
1)
-20 ... +70 °C
-
Climate class
per DIN EN 60654-1
Cx (-40 … +85 °C, 5 % up
to 95 % rel. air humidity)
Bx (-20 … +70 °C, 5 %
up to 95 % rel. humidity)
Maximum permissible
humidity
per DIN IEC 68-2-30 Var. 2
100 % relative humidity
(unlimited with insulated
sensor connection wires),
moisture condensation
permissible
90 % relative humidity
Vibration
10 … 2000 Hz 5 g DIN IEC 68-2-6
Shock
DIN IEC 68-2-27 30 g
Salt mist
DIN IEC 68-2-11
Case material
Plastic, PBT, glass fibre
reinforced
Plastic
Ingress protection
per IEC 60529/EN 60529
IP 00
IP 20
1) without explosion protection
For further specifications see WIKA data sheet TE 12.03 and the
order documentation.
For further important safety instructions for operation in
hazardous areas see chapter "10. Notes for mounting
and operating in hazardous areas".
3. Specifications