Commissioning, operation – WIKA T12 Benutzerhandbuch
Seite 17

GB
3211517.07
07/2010
GB/D
WIKA operating instructions temperature transmitter T12
17
Installation by means of DIN rail adapter
If the mechanical adapter, available as an accessory, is used the
T12.10 head transmitters can also be fixed on a DIN rail.
6.1.2 Transmitter in rail mounting version (model T12.30)
Fasten the rail-mounting case (model T12.30) onto a 35 mm top-hat
rail (IEC 60715) by simply locking it into place without the need for
any tools.
Disassemby is achieved by unlocking the locking element.
3173801.C
6. Commissioning, operation
Check the screw length before fixing the transmitter to the measuring
insert: insert the screw into the circular plate and verify length of 4 mm!
CAUTION!
Do not exceed the maximum permissible screw length!
The transmitter will be damaged if the screws are screwed
further than 4 mm into the bottom of the transmitter.
Mounting in connection head
Insert the measuring insert with the mounted transmitter into the
protective sheath and secure into the connecting head using screws
in pressure springs.