17

Installation by means of DIN rail adapter

If the mechanical adapter, available as an accessory, is used the

T12.10 head transmitters can also be fixed on a DIN rail.

6.1.2 Transmitter in rail mounting version (model T12.30)

Fasten the rail-mounting case (model T12.30) onto a 35 mm top-hat

rail (IEC 60715) by simply locking it into place without the need for

any tools.

Disassemby is achieved by unlocking the locking element.

3173801.C

6. Commissioning, operation

Check the screw length before fixing the transmitter to the measuring

insert: insert the screw into the circular plate and verify length of 4 mm!

CAUTION!

Do not exceed the maximum permissible screw length!

The transmitter will be damaged if the screws are screwed

further than 4 mm into the bottom of the transmitter.

Mounting in connection head

Insert the measuring insert with the mounted transmitter into the

protective sheath and secure into the connecting head using screws

in pressure springs.