2 parameter handling (save, load default) – Baumer BA_DSRT_22DJ Benutzerhandbuch

Seite 32

Advertising
background image

Manual_CANopen_StrainLink_EN_V3_05.doc

32/65

Baumer

22.07.11/dam

Frauenfeld, Switzerland

6.2 Parameter handling (save, load default)

The following changeable objects can be saved in the EEPROM:

Object

Name

Default value

1017

Producer heartbeat time

00h

Disabled

1400

Receive PDO1 – COB-ID + PDO valid,
sub-index 1

40’00’02’xxh

COB-ID = 200h+ID, Receive PDO
enabled

PDO1 – COB-ID + PDO valid , sub-index 1 40’00’01’xxh

COB-ID = 180h+ID, PDO enabled

PDO1 – transmission type , sub-Index 2

FFh

Transmit after event timer

1800

PDO1 – event time , sub-index 5

03’E8h

1000 ms

PDO2 – COB-ID + PDO valid , sub-index 1 40’00’02’xxh

COB-ID = 280h+ID, PDO enabled

PDO2 – transmission type , sub-index 2

02h

Transmit after 2

nd

SYNC

1801

PDO2 – event time , sub-index 5

03’E8h

1000 ms

PDO3 – COB-ID + PDO valid , sub-index 1 40’00’03’xxh

COB-ID = 380h+ID, PDO enabled

PDO3 – transmission type , sub-index 2

FEh

Asynchronous, transmit after value
change

1802

PDO3 – event time , sub-index 5

03’E8h

1000 ms

1A00

Transmit PDO1 mapping, sub-index 1

71’30’01’10h

Index 7130, sub-index 1 mapped

1A01

Transmit PDO2 mapping, sub-index 1

71’30’01’10h

Index 7130, sub-index 1 mapped

1A02

Transmit PDO3 mapping, sub-index 1

20’04’00’10h

Index 2004, sub-index 0 mapped

2000

Averaging time

00’30h

30 ms

2001

Save autozero automatically

00h

Automatically storage disabled

2002

IIR-filter cut-off frequency

00’00h

IIR filter disabled

2100

Baud rate

03h

125 kBaud

2101

Identification (7 bit)

01h

ID 1

2112

Transmit data type 16/24bit

71’30h

16bit data type

7133

Interrupt delta input PV 16bit

00h

Disabled

8133

Interrupt delta input PV 24bit

00h

Disabled

6.2.1

Store parameters

With object 1010h, the current parameters can be stored in EEPROM. The indices which are stored can be
seen in the table at the beginning of Section 6.2.

Storage takes place when the “save” message is sent in ASCII code to index 1010h, sub-index 1. The
message thus has the following structure:

ID

DLC

Byte1

Byte2

Byte3

Byte4

Byte5

Byte6

Byte7

Byte8

600h + ID

8

22h

10h

10h

01h

73h

61h

76h

65h


Response from CANopen strain link:

ID

DLC

Byte1

Byte2

Byte3

Byte4

Byte5

Byte6

Byte7

Byte8

580h + ID

8

60h

10h

10h

01h

0

0

0

0

Advertising