Manual_CANopen_StrainLink_EN_V3_05.doc
46/65
Baumer
22.07.11/dam
Frauenfeld, Switzerland
Change of transmit PDO from enable to disable (sub-index 1):
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
600h + ID
8
22h
00h
18h
01h
81h
01h
0
40h
Byte 5 + 6:
81’01h
01’81h (LSB first)
180h + ID 1 (COB-ID)
Byte 8:
40h
PDO enabled and RTR not supported
C0h
PDO disabled and RTR not supported
Response from CANopen strain link:
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
580h + ID
8
60h
00h
18h
01h
0
0
0
0
Change of transmission type (sub-index 2):
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
600h + ID
8
22h
00h
18h
02h
FFh
0
0
0
Byte5
01h – F0h
transmit after n
th
Sync (1 – 240)
FEh
transmit when interrupt delta input
(interrupt delta input value is set with object 7133h)
FFh
transmit when event timer
(Event timer is set with sub-index 05h)
Response from CANopen strain link:
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
580h + ID
8
60h
00h
18h
02h
0
0
0
0
The event timer defines in which cycle the PDO will be transmitted.
The value range is fixed between 0…2
16
– 1 = 65535 (ms).
Change of event timer (sub-index 5):
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
600h + ID
8
22h
00h
18h
05h
E8h
03h
0
0
Byte 5 + 6:
E8’03h
03’E8h (LSB first)
Event timer 1000 ms (Default value)
Response from CANopen strain link:
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
580h + ID
8
60h
00h
18h
05h
0
0
0
0
Too small values make no sense, because they overload the bus and the measured values may still not be
updated (see start of this section).
The PDO parameters are not stored automatically, must be done with object 1010h.