4 manufacturer specific objects – Baumer BA_DSRT_22DJ Benutzerhandbuch
Seite 39
Manual_CANopen_StrainLink_EN_V3_05.doc
39/65
Baumer
22.07.11/dam
Frauenfeld, Switzerland
6.4 Manufacturer specific objects
The definition of the following objects is manufacturer specific. They are used to set the CANopen strain link.
List of supported objects:
Object Name
2000
Averaging time
2001
Store autozero
2002
IIR filter cut-off frequency
2003
Autozero
2004
Status autozero
2100
Baud rate
2101
Identification
2112
Transmit data type 16/24bit
6.4.1
Averaging time
The average time specifies the time in ms over which the measured values are arithmetically averaged. The
average time can be set between 0..1000 (0..3E8h).
The sensor internal averaging contains a 32bit buffer. If an averaging time >32ms is selected, just every 2
nd
measurement is used. With averaging time >64ms just every 3
rd
value is used, and so on.
If the IIR-filter is enabled, the averaging should be disabled and vice versa.
Read averaging time (object 2000h):
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
600h + ID
8
40h
00h
20h
00h
0
0
0
0
Response from CANopen strain link:
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
580h + ID
8
4Bh
00h
20h
00h
1Eh
00h
0
0
Byte 5 + 6:
1E’00h
00’1Eh (LSB first)
30ms (Default value)
Change of averaging time:
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
600h + ID
8
22h
00h
20h
00h
64h
00h
0
0
Byte 5 + 6:
64’00h
00’64h (LSB first)
100ms
Response from CANopen strain link:
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
580h + ID
8
60h
00h
20h
00h
0
0
0
0