Manual_CANopen_StrainLink_EN_V3_05.doc

37/65

Baumer

22.07.11/dam

Frauenfeld, Switzerland

6.3.8

Process value 24bit

Read process value 24bit (object 8130h):

ID

DLC

Byte1

Byte2

Byte3

Byte4

Byte5

Byte6

Byte7

Byte8

600h + ID

8

40h

30h

81h

01h

0

0

0

0


Response from CANopen strain link:

ID

DLC

Byte1

Byte2

Byte3

Byte4

Byte5

Byte6

Byte7

Byte8

580h + ID

8

47h

30h

81h

01h

80h

38h

01h

0


Byte 5 - 7:

80'38'01h

01’38'80 (LSB first)

80000

80000 / 10

Number decimal digits

(6132) + unit(6131) = 800.00 µ

ε


The process value is quoted as 24-bit Integer double complement.
The object 2112h is changing the process value from 16bit (object 7130h) to 24bit (object 8130h) and vice
versa.

Example of negative strain:

ID

DLC

Byte1

Byte2

Byte3

Byte4

Byte5

Byte6

Byte7

Byte8

580h + ID

8

4Bh

30h

81h

01h

80h

C7h

FEh

0


Byte 5 - 7:

80'C7'FEh

FE’C7'80 (LSB first)

-80000

-80000/10

Number decimal digits

(6132) + unit(6131) = -800.00 µ

ε


The object 8130h is read only.

6.3.9

Interrupt delta input

After the delta function is activated, when the threshold is passed the current process value is sent via PDO
and a new threshold value is set. At the next over or undercut the threshold again a PDO will be sent.
(Threshold = momentary process value +/- delta value)

t

2

*

d

e

lt

a

v

a

lu

e

A:

Activation of delta function via
PDO Transmission Type

B-F:

Process value is sent via PDO,
new threshold value is set

P:

Process value

t:

Time

B

C

D E F

A

P

With the object 7133h (16bit) and 8133h (24bit) the interrupt delta input value can be set and read.

The delta function is activated or deactivated via the transmission type of the PDO1 (object 1800h), PDO2
(object 1801h) and PDO3 (object 1802h).