Baumer BA_DSRT_22DJ Benutzerhandbuch
Seite 40
Manual_CANopen_StrainLink_EN_V3_05.doc
40/65
Baumer
22.07.11/dam
Frauenfeld, Switzerland
6.4.2
Store autozero
Store autozero should be disabled with cyclical autozero applications.
Read status of store autozero (object 2001h):
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
600h + ID
8
40h
01h
20h
00h
0
0
0
0
Response from CANopen strain link:
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
580h + ID
8
4Fh
01h
20h
00h
01h
0
0
0
Byte 5:
01h
0
save after autozero automatically disabled
1
save after autozero automatically enabled
Change of status of store autozero:
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
600h + ID
8
22h
01h
20h
00h
00h
0
0
0
Byte 5:
00h
0
save after autozero automatically disabled
Response from CANopen strain link:
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
580h + ID
8
60h
01h
20h
00h
0
0
0
0
6.4.3
IIR filter cut-off frequency
This object contains the cut-off frequency of a IIR-filter 1
st
order. The calculation of the filter coefficient is
made for the sampling rate of 1000 samples per second. The cut-off frequency can be chosen between
0...499Hz (0...1F3h). The value 0 disables the IIR-filter (default value). If the filter is enabled, the averaging
(object 2000h) should be disabled and vice versa.
Read IIR-filter cut-off frequency (object 2002h):
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
600h + ID
8
40h
02h
20h
00h
0
0
0
0
Response from CANopen strain link:
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
580h + ID
8
4Bh
02h
20h
00h
0Ah
00h
0
0
Byte 5 + 6:
00’00h
00’00h
disabled (Default value)
Change of IIR-filter cut-off frequency:
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
600h + ID
8
22h
02h
20h
00h
64h
00h
0
0
Byte 5 + 6:
64’00h
00’64h
100Hz
Response from CANopen strain link:
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
580h + ID
8
60h
02h
20h
00h
0
0
0
0